<?xml version="1.0" encoding="UTF-8"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/"
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
                             http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-11-25T17:14:23Z</responseDate>
  <request verb="GetRecord" identifier="oai:vu.lt:elaba:2082452" metadataPrefix="oai_dc">https://epublications.vu.lt/oai</request>
<GetRecord>
<record>
  <header>
    <identifier>oai:vu.lt:elaba:2082452</identifier>
    <datestamp>2026-07-02T20:57:29Z</datestamp>
    <setSpec>openaire</setSpec><setSpec>NDLTD</setSpec><setSpec>DRIVER</setSpec>
  </header>
  <metadata>
<oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/"><dc:title>Elektrotechninių įrenginių elektrodinaminių bandymų metodikos ir priemonių tyrimas /</dc:title><dc:title>The investigation of elektrotechnical equipment‘s electrodynamics tests methodology and devices.</dc:title><dc:creator>Macevičius, Rimvydas,</dc:creator><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:subject>Medium voltage semi-metalclad type switchgear systems ; short – time and withstand current tests ; laboratory</dc:subject><dc:description>Stock company „ELGA“ is constantly developing an air insulated medium voltage semi-metalclad type switchgear systems construction, so it happens that we need to do short – time and withstand current tests for new complemented equipment. The Master thesis analyses short – time and withstand current tests laboratory for in company prefab medium voltage semi-metalclad type switchgear systems USN-10, USN-20 designed to be used for 6 ÷ 10, 24 kV voltage, and 50Hz frequency power distribution, connected feeder with over current and overload protection. Various companies&apos; circuit breakers for example „ABB“; „SIEMENS“; „VEI“ etc are installed on extractive element (trolley) in cubicle. Normative standards sustaining how the tests should be made, test laboratory formative elements resistant’s, short – time and withstand current calculation, test scheme and test conditions are presented in the Master thesis.</dc:description><dc:publisher>Institutional Repository of Vilnius University</dc:publisher><dc:contributor>Turauskas, Zigmantas</dc:contributor><dc:type>info:eu-repo/semantics/masterThesis</dc:type><dc:language>lit</dc:language><dc:date>2008</dc:date><dc:format>application/pdf</dc:format><dc:relation>https://epublications.vu.lt/object/elaba:2082452/2082452.pdf</dc:relation><dc:identifier>https://repository.vu.lt/VU:ELABAETD2082452&amp;prefLang=en_US</dc:identifier></oai_dc:dc>  </metadata>
</record>

</GetRecord></OAI-PMH>
