<?xml version="1.0" encoding="UTF-8"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/"
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
                             http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-11-26T10:40:13Z</responseDate>
  <request verb="GetRecord" identifier="oai:vu.lt:elaba:308150850" metadataPrefix="oai_dc">https://epublications.vu.lt/oai</request>
<GetRecord>
<record>
  <header>
    <identifier>oai:vu.lt:elaba:308150850</identifier>
    <datestamp>2026-07-07T05:58:46Z</datestamp>
    <setSpec>openaire</setSpec><setSpec>NDLTD</setSpec><setSpec>DRIVER</setSpec>
  </header>
  <metadata>
<oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/"><dc:title>Neinvaziniais vaizdiniais tyrimais ir dirbtiniu intelektu suplanuotų aritmijų abliacijos procedūrų įvertinimas /</dc:title><dc:title>Evaluation of arrhythmia ablation procedures planned using non-invasive imaging studies and artificial intelligence.</dc:title><dc:creator>Radavičius, Vytautas,</dc:creator><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:description>Background Images from computed tomography (CT) imported into specialized image processing systems perform image segmentation and integration with electroanatomic maps. Integrating non-invasive artificial intelligence (AI) and decrement evoked potential (DEEP) mapping into ablation procedures may improve substrate targeting in ischemic ventricular tachycardia (VT) ablation. Methods Patients (n=4) with ischemic cardiomyopathy and scar-related VT were included between 2024 and 2025 into the pilot observational study. Pre-procedural CT scans were processed using an AI-guided imaging platform to identify scar distribution and predicted isthmuses. High-density DEEP mapping was performed intra-procedurally. Ablation primarily targeted DEEP sites co-localizing AI-defined isthmuses. Non-inducibility was tested after the ablation of all primary targets using the 400/S2/S3/S4 stimulation protocol and pharmacological provocation testing. Results All patients were male with a mean age of 69.2 ± 5.7 years, mean left ventricular ejection fraction (LVEF) of 32.2 ± 13.2%, and a mean number of 13,67 ± 18,93 discharges of implantable cardioverter-defibrillators (ICDs). Patients presented with an average scar volume of 26.59 ± 6.96 ml, 10.5 ± 5.72 pre-defined VT-dependent isthmuses and 2 ± 1.41 primary inducible VTs per patient. Pre-procedural PAINESD risk score averaged 14.75 ± 5.12. Primarily ablation tactic resulted in VT non-inducibility in all patients. During a median follow-up of 10 ± 2.83 months (range 6-12 months), no sustained VT recurrences were observed. Freedom from non-sustained VT was 50% at 7 months. Conclusion This pilot experience suggests that combining AI-derived anatomical isthmus prediction with DEEP functional mapping is feasible and may enhance substrate targeting in ischemic VT ablation. Larger comparative studies are required to determine its impact on long-term outcomes.</dc:description><dc:publisher>Institutional Repository of Vilnius University</dc:publisher><dc:type>info:eu-repo/semantics/masterThesis</dc:type><dc:language>lit</dc:language><dc:date>2026</dc:date><dc:format>application/pdf</dc:format><dc:relation>https://epublications.vu.lt/object/elaba:308150850/308150850.pdf</dc:relation><dc:identifier>https://repository.vu.lt/VU:ELABAETD308150850&amp;prefLang=en_US</dc:identifier></oai_dc:dc>  </metadata>
</record>

</GetRecord></OAI-PMH>
