Title |
Quantitative assessment of liver impairment in chronic viral hepatitis with [99mTc]Tc-Mebrofenin: a noninvasive attempt to stage viral hepatitis-associated liver fibrosis / |
Authors |
Jocius, Donatas ; Vajauskas, Donatas ; Mikelis, Kipras ; Jokubauskienė, Skirmantė ; Jakutienė, Jolita ; Strupas, Kęstutis ; Tamošiūnas, Algirdas Edvardas |
DOI |
10.3390/medicina58101333 |
Full Text |
|
Is Part of |
Medicina.. Basel : MDPI. 2022, vol. 58, iss. 10, art. no. 1333, p. [1-16].. ISSN 1010-660X. eISSN 1648-9144 |
Keywords [eng] |
99mTc-mebrofenin ; chronic liver disease ; hepatobiliary scintigraphy ; liver fibrosis |
Abstract [eng] |
Background and objectives—Chronic viral hepatitis B and C infections are one of the leading causes of chronic liver impairment, resulting in liver fibrosis and liver cirrhosis. An early diagnosis with accurate liver fibrosis staging leads to a proper diagnosis, thus tailoring correct treatment. Both invasive and noninvasive techniques are used in the diagnosis and staging of chronic liver impairment. Those techniques include liver biopsy, multiple serological markers (as either single tests or combined panels), and imaging examinations, such as ultrasound or magnetic resonance elastography. Nuclear medicine probes may also be employed in staging liver fibrosis, although the literature scarcely reports this. The purpose of our study was to investigate whether a dynamic liver scintigraphy with [99mTc]Tc-mebrofenin has any value in staging or grading chronic liver damage. Materials and Methods—We prospectively enrolled patients with chronic viral hepatitis B and C infection referred for liver biopsy. All patient underwent dynamic liver scintigraphy with 99mTc-mebrofenin prior to liver biopsy. Dynamic liver scintigraphy was performed immediately after intravenous tracer injection for 30 min scanning time. Multiple scintigraphy parameters were calculated (whole liver lobe and focal area time to peak (TTP), 30 min to peak ratio (30/peak), whole lobe and focal area slope index in 350 s (slope_350). Liver biopsy took place shortly after imaging. Results—We found that many dynamic scintigraphic parameters are positively or negatively associated with different stages of liver fibrosis. The main parameters that showed most value are the ratio between 30 min and the peak of the dynamic curve (30/peak_dex (ratio)), and liver clearance corrected for body surface area and liver area (LCL_m2_dm2 (%/min/m2/dm2)). Conclusions—Our present study proves that conducting dynamic liver scintigraphies with [99mTc]Tc-mebrofenin has potential value in staging liver fibrosis. The benefits of this method, including whole liver imaging and direct imaging of the liver function, provide an advantage over presently used quantitative imaging modalities. |
Published |
Basel : MDPI |
Type |
Journal article |
Language |
English |
Publication date |
2022 |