| Title |
Performance of a triple-GEM demonstrator in p p collisions at the CMS detector |
| Authors |
Juodagalvis, Andrius |
| DOI |
10.1088/1748-0221/16/11/P11014 |
| Full Text |
|
| Is Part of |
Journal of instrumentation.. Bristol : IOP Publishing Ltd.. 2021, vol. 16, iss. 11, art. no. P11014, p. [1-11].. ISSN 1748-0221 |
| Keywords [eng] |
Micropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc) ; Muon spectrometers ; Performance of High Energy Physics Detectors |
| Abstract [eng] |
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high 𝜂 region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high 𝑝𝑇 uons in proton-proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector. |
| Published |
Bristol : IOP Publishing Ltd |
| Type |
Journal article |
| Language |
English |
| Publication date |
2021 |
| CC license |
|