Title Vyrų šlapimo nelaikymo gydymas implantuojant dirbtinį sfinkterį AMS 800 /
Translation of Title Male urinary incontinence treatment with AMS 800 artificial urinary sphincter.
Authors Černiauskienė, Aušra ; Snicorius, Marius ; Valatka, Paulius
DOI 10.15388/LietChirur.2017.1.10487
Full Text Download
Is Part of Lietuvos chirurgija.. Vilnius : Lietuvos chirurgų asociacija. 2017, T. 16, Nr. 1, p. 17-26.. ISSN 1392-0995. eISSN 1648-9942
Keywords [eng] male urinary incontinence ; artificial urinary sphincter ; radical prostatectomy ; AMS 800 ; review
Abstract [eng] Objective Our purpose is to review results of AMS 800 artificial urinary sphincter implantation for treatment of male stress urinary incontinence. To evaluate indications, contraindications, patient assessment, operative technique and complications of AMS 800 device. Materials and methods We used up to date literature of PubMed database. Results Success rates of artificial urinary sphincter AMS 800 vary between 61% and 100%. 80 – 90% of patients were satisfied with the outcome and would recommend having the surgery. The complication rates are generally low and varies between 1–31%. AMS 800 5-year functioning without complications rates vary between 59% and 79%. Conclusions AMS 800 artificial urinary sphincter is highly effective and time tested treatment of moderate and severe stress urinary incontinence. This device shows effective results and significantly improves the quality of life for appropriate selected patients.
Published Vilnius : Lietuvos chirurgų asociacija
Type Journal article
Language Lithuanian
Publication date 2017
CC license CC license description