Title Calibration of video-oculographical eye-tracking system /
Authors Ramanauskas, Nerijus
Full Text Download
Is Part of Electronics and electrical engineering = Электроника и электротехника = Elektronika ir elektrotechnika.. Kaunas : Kauno technologijos universitetas. 2006, Nr. 8(72), p. 65-68.. ISSN 1392-1215
Abstract [eng] Video-oculography (VOG) is the most suitable eye tracking method in Human Computer Interaction. The precise mapping from image co-ordinates to computer monitor screen co-ordinates in real time is necessary for efficient computer control. During this study, the calibrations techniques were investigated. It was noticed that, there is no significant difference between a mapping with developed model, describing eye image formation process in the sensor, and with polynomial calibration. Polynomial calibration model do not allow a free head motion and requires frequent recalibration. A model based mapping is tolerant to head motions. An improved model could take an advantage over polynomial mapping.
Published Kaunas : Kauno technologijos universitetas
Type Journal article
Language English
Publication date 2006
CC license CC license description